HPLC is widely used in pharmaceutical, chemical, environmental, food and life-science laboratories. Water may be used as a mobile-phase component, diluent, reagent, blank and cleaning solution.
Water is used throughout clinical, healthcare and pathology laboratories for reagent preparation, analyser operation, washing, dilution, staining, sterilization support and general laboratory procedures.
Variations in ionic purity, organic contamination, microbial quality or particulate load can affect reagent stability, analyser performance, calibration, blank values and test reproducibility.
The required water quality depends on:
Water systems for healthcare laboratories should provide consistent water quality together with dependable operation, suitable monitoring and documented maintenance.
Purified Water for Consistent Diagnostic Testing
Clinical diagnostic laboratories perform a wide range of biochemical, immunological, haematological and molecular tests. Water may be used directly by analysers or for preparing reagents, controls, stains, buffers and cleaning solutions.
Even small changes in water quality can influence sensitive analytical reactions.
Common Uses of Water
Poor Water Quality May Cause
Recommended Water Quality
The required water grade should be selected according to the analyser and test method.
Depending on the application, laboratories may require:
The analyser manufacturer’s water specification should always be reviewed before selecting or connecting a water system.
Best Practices
Carefully Controlled Water for Sensitive Reproductive Laboratories
IVF laboratories operate highly controlled environments where contamination, chemical vapours, microorganisms and endotoxins may affect sensitive biological procedures.
Water may be used for preparing laboratory solutions, cleaning, rinsing, equipment support and other controlled processes. The required water quality depends on whether the water is used for general laboratory support or in a procedure that may directly or indirectly affect gametes, embryos or culture conditions.
Common Uses of Water
Poor Water Quality May Cause
Recommended Water Quality
Water requirements should be defined according to the specific use.
IVF laboratories may require:
Important Consideration
High resistivity alone does not confirm that water is:
Water used in procedures that may directly affect reproductive material should follow the laboratory’s validated protocol and applicable product, equipment and quality requirements.
Best Practices
Explore Water Solutions for IVF Laboratories
Reliable Purified Water for Multidisciplinary Hospital Testing
Hospital laboratories often support clinical chemistry, microbiology, pathology, haematology, immunology, molecular diagnostics and blood-related testing.
Different departments may require different water qualities and consumption volumes. A water system should therefore be selected according to the complete hospital laboratory requirement rather than only one instrument.
Common Uses of Water
Poor Water Quality May Cause
Recommended Water Quality
A hospital laboratory may require several water grades:
A centralized system may support several departments when storage, distribution, pressure and microbial control are properly designed.
Best Practices
Centralized Water Distribution
A centralized system may offer:
The distribution loop should be designed to avoid dead legs, excessive pressure loss and stagnant sections.
Explore Water Solutions for Hospital Laboratories
Reliable Purified Water for Multidisciplinary Hospital Testing
Hospital laboratories often support clinical chemistry, microbiology, pathology, haematology, immunology, molecular diagnostics and blood-related testing.
Different departments may require different water qualities and consumption volumes. A water system should therefore be selected according to the complete hospital laboratory requirement rather than only one instrument.
Common Uses of Water
Poor Water Quality May Cause
Recommended Water Quality
A hospital laboratory may require several water grades:
A centralized system may support several departments when storage, distribution, pressure and microbial control are properly designed.
Best Practices
Centralized Water Distribution
A centralized system may offer:
The distribution loop should be designed to avoid dead legs, excessive pressure loss and stagnant sections.
Explore Water Solutions for Hospital Laboratories
Water-quality parameter | Importance |
Conductivity and resistivity | Indicate ionic contamination that may affect reagents, analysers and calibration |
Microbial count | Important for stored water, analyser lines and sensitive biological procedures |
TOC | Organic contamination may affect sensitive reactions and instrument backgrounds |
Endotoxins | May be important for cell-related and other biologically sensitive applications |
Particles | May block probes, valves, filters and analyser tubing |
Hardness | Can cause scaling in analysers, washers, autoclaves and equipment |
Chlorine | May damage membranes and interfere with certain procedures |
Consistent pressure and flow | Required for reliable analyser operation |
Water-quality stability | Supports reproducible testing and quality-control performance |
Analyser-Feed Water
Water supplied directly to an analyser should meet the equipment manufacturer’s specification for conductivity, microbial quality, pressure, flow and other relevant parameters.
Reagent-Preparation Water
Water used for reagents, buffers, standards or controls should not introduce contamination that affects the analytical method.
Sterile Water
Sterile water has undergone a validated process intended to remove or inactivate viable microorganisms. Ultrapure water is not automatically sterile.
Endotoxin-Controlled Water
This water is prepared and handled to meet a defined endotoxin requirement. It may be necessary for sensitive biological applications.
General Laboratory Water
RO or purified water may be suitable for washing, autoclave feed and other utility applications, provided that equipment specifications are met.
These categories should not be considered interchangeable without evaluating the actual procedure.
Water-related problems in clinical laboratories may originate from:
A systematic investigation should identify where water quality begins to deteriorate.
Follow Instrument Requirements
Check the water-quality, pressure and flow requirements of every connected analyser or piece of equipment.
Separate Water Grades Where Necessary
General washing, analyser feed and sensitive reagent preparation may require different water qualities. The system should provide the correct quality for each use.
Control Microbial Growth
Use protected storage, suitable vent filtration, circulation, UV treatment and sanitization where required.
Maintain Stable Supply
Clinical laboratories may operate continuously or process urgent samples. Production and storage capacity should support both daily and peak demand.
Monitor Critical Parameters
Depending on the application, monitor:
Maintain Documentation
Record water-quality results, sanitization, consumable replacement, alarms and service work. Documentation supports troubleshooting and laboratory quality procedures.
Plan for Continuity
Where water is essential to critical diagnostic services, consider:
The appropriate system should be selected according to:
A combination of pretreatment, RO, EDI, UV, storage, circulation, polishing and final filtration may be used to provide the required water qualities.
Share the following details with TKA:
TKA can help evaluate the appropriate purification technology, production capacity, storage, distribution, monitoring and point-of-use configuration for your laboratory.
TKA Ultrapure Water Technologies India Pvt. Ltd.
Unit 311, Globe Business Park,
Kalyan – Badlapur Road, Laxmi Nagar, Ambarnath (W) 421501
Thane, Maharashtra, India
Phone: +91-9987174888 / +91-9867964888
Email: info@tkaindia.com
© 2026 TKA India | All Rights Reserved.
TKA Ultrapure Water Technologies India Pvt. Ltd. is an Indian company focused on the design, manufacture and support of laboratory water purification systems… Read More